3M™ Zeta Plus™ ZB Series Filter Cartridge Z16E08AA 90ZB05A, 16 in Diameter, 8 Cell, Silicone, 1 Per Case

Recommended for secondary polishing cell clarification applications, such as DNA removal, in recombinant proteins, such as monoclonal antibodies, 3M™ Zeta Plus™ EXT Series Filter Cartridge with ZB Series Media minimizes hold-up volume and maximize product recovery, while providing a particle free permeate solution for downstream processing.
Price: $1093.44

(Case of 1 Each)

Estimated Lead Time is 150 working days.
  • $1093.44
  • Case of 1 - $1093.44
Qty:  
  • Return Policy

    Our site states no returns allowed; however, in addition to a few exceptions, if your order is defective or damaged, the order will be replaced with good product. 

    • Weight
      14 lbs
    • SKU
      7010314498
    • UPC/ISBN
      00054007974406
  • Lead Time
    150
  • Manufacturer
    3M
  • SAP
    7010314498
  • 3M ID
    70020307818
  • UPC
    00-54007-97440-6
  • Product Formal Name
    3M™ Zeta Plus™ ZB Series Filter Cartridge Z16E08AA 90ZB05A, 16 in Diameter, 8 Cell, Silicone, 1 Per Case
  • Brand
    Zeta Plus
  • Case Unit
    Case of 1
  • Unit of Measure
    Each
  • Estimated Lead Time
    150
  • Inventory Status Code
    N
  • Country of Origin
    USA
  • Return Policy
    No Return
  • Box Length (in)
    19.250
  • Box Width (in)
    19.250
  • Box Height (in)
    10.250
  • Bullets
    • Bullet 1
      - Suitable for primary cell culture filtration or intermediate polishing applications in R&D, Process Development or manufacturing of recombinant protein drugs such as monoclonal antibodies
      - Made using cellulose fibers, diatomaceous earth and a binding resin that imparts a positive charge (quaternary amine), ZB grade media filters particles from process solutions through mechanical sieving and electrokinetic adsorption mechanisms
      - Wide range of filter pore sizes (0.1 to 4 µm) and a dual layer lenticular construction allows for optimizing filter throughput and filtrate quality
      - Scaleable single use filter portfolio enables using the same filtration platform process liquids volumes of 0.5 to 20,000 liters
      - Unique filter capsule design minimizes hold-up volume and maximizes product recovery, while reducing the need for cleaning validation; translucent plastic shell allows easy detection of the liquid level for real time monitoring of the filtration process and to minimize flush volumes
      - Cam-lock connections on Zeta Plus Encapsulated capsules, and holder design allows for easy assembly and tear down of filtration system and improving productivity of manufacturing clean room
  • Transportation
    • ECCN Number
      EAR99
    • Harmonized Tariff Schedule Number
      8421290065
    • UNSPSC Code
      40161500
    • United States Department Of Transportation Ground US DOT, 49 CFR
      NOT REGULATED
    • United States Department Of Transportation Vessel US DOT, 49 CFR
      NOT REGULATED
    • NMFC Item
      069100
    • NMFC Class
      100.0
    • NMFC Sub
      06
    • Transport Protective Service
      PROTECTIVE SERVICE NOT REQUIRED
    • International Air Transport Association
      NOT REGULATED
    • International Maritime Organization
      NOT REGULATED
    • Flashpoint Transport
      No Flash Point
  • SKU
    7010314498
  • UPC/ISBN
    00054007974406

3M™ Zeta Plus™ EXT Series Filter Cartridge with ZB Series Media are optimized for secondary polishing applications during filtration of mammalian cell harvest fluids, clarification of high protein concentration feed streams and for optimal protection of downstream sterilizing grade membrane filters. 3M™ Zeta Plus™ EXT Series Filter Cartridge with ZB Series Media are composed of inorganic filter aid, cellulose and a resin system that imparts a positive charge to the filter matrix. The single use format reduces the need for cleaning validation and minimizes filtration set up time for biopharma process development scientists.3M™ Zeta Plus™ EXT Series Filter Cartridge with ZB Series Media grade media consist of two distinct layers, or zones" of filter media with the upstream zone more open than the downstream zone. This structure enhances the contaminant holding capacity of the filter media, since larger particles are trapped in the upper zone of the filter media and smaller particles are trapped in the lower zone, reducing premature plugging and extending service life.3M™ Zeta Plus™ EXT Series Filter Cartridge with ZB Series Media are optimized for clarification of mammalian cell harvest fluids and for protection of downstream sterilizing grade membrane filters. Their strong positive charge provides enhanced reduction of negatively charged contaminants compared to a mechanical filtration mechanism alone. In solution cells, cellular debris, endotoxins, and nucleic acids (DNA, RNA) carry a negative charge. 3M ,s application of positive zeta potential to ZB filter media creates a filter matrix that enhances the capture of negatively charged contaminants for maximum filtration performance. The strong positive charge over a broad pH range makes these filters ideal for cell broth clarification and for protection of downstream membrane filters.Regulatory Support3M™ Zeta Plus™ filters with ZB media are manufactured in accordance with an ISO 13485 Registered Quality Management system. All filter components success fully passed the USP Class VI Biological Reactivity Tests. Each filter includes certificate of quality and, to ease validation and regulatory submission. These filters are registered with the US FDA with a drug master file and a comprehensive regulatory support file is also available.Grade SelectionThe 3M™ Zeta Plus™ series with ZB filter media are available in six grades. Figure below, is provided as a guide to proper grade selection based on nominal retention ratings and can be used in conjunction with the recommendations in Table below to determine the appropriate filter grade for your application. Operating conditions and the fluid being filtered impact retention performance. 3M recommends small scale pilot runs to confirm grade selection prior to scale-up. 3M ,s application engineering team can assist in grade selection as well as assist in on-site evaluations. Filter system optimization can also be conducted at our laboratory facilities.A History of InnovationFor more than a century, 3M has applied innovation and technology to improving customers' lives and supporting their business goals. Today the company, from its headquarters in St. Paul, Minnesota, serves industrial and commercial customers and consumers in nearly 200 countries. The 3M brand, across thousands of products, represents consistency, superior quality and value. Success begins with a culture of creative collaboration that inspires a never-ending stream of powerful technologies and product solutions that make life be

FREIGHT FREE on purchases with a subtotal of $4000.00 or more.

Our site states no returns allowed; however, if your order is defective or damaged, the order will be replaced with good product. In addition, we will attempt to return all your product (not only damaged product) if 3M grants the return based on various factors. Some items may be approved for return pending approval from 3M. Some but not all factors include if the item is a 3M stock item and elapsed time from receipt of product to issued return request. Note: 3M will not accept a return if the item is made to order or if the order is less than $600.00. Please double check accuracy of your orders prior to placing them. Details regarding if an item is stock or made to order can be found in the specifications tab of the item page. N = Made to order Item. S = Stock Item. We cannot guarantee any returns.

If you received a defective or damaged shipment, please email us at support@industrialgeneralstore.com explaining in detail the reason for requesting a replacement so we can contact 3M and initiate the return and new shipment.